Specification
320*240*285 mm
Product Description
Model | OCL-800 | Operating tempeture | -25ºC~45ºC |
Power | 280/315kw | Operation relative humidity | Not exceeding 90% |
Size(L*W*H) | 320*240*285mm | Dielectric Strength | Iron core - winding resistance 3000V/50HZ, no arc breakdown for 60 seconds |
Installation dimensions | 170*135mm | Hs Code | 8504500000 |
Material | Copper | Warranty | 18 months |
The output reactor for the frequency converter , which passes through AC power. Its function is to compensate for the capacitance charging current of long wires, limit the voltage rise rate of cables, improve the output waveform of frequency converters, absorb the damage of grid harmonics to motors, and increase and extend the service life of motors.Product features:
1. The iron core is made of high-quality cold-rolled silicon steel sheets, which undergo high-speed punching and shearing, and have high-quality characteristics such as small burrs, good integrity, low loss, and low noise.
2. The coil adopts high-quality copper foil and aluminum foil as conductor materials, and is standardized by professional foil winding machines. The coil has the characteristics of good flatness and overall aesthetics.
3. The terminals are led out using high-quality copper bars, which are convenient for wiring and have low heat generation, ensuring the safety of the electrical system.
4. In the assembly engineering of reactors, key components are made of non-magnetic materials and pre baked and vacuum coated to firmly integrate the reactor core and coil, greatly reducing noise during operation. ParameterOutput Reactor for Frequency Converter |
Model | Power | Voltage drop(V) | Dimension(L*W*H) | Installation dimensions(L*W) | Material |
OCL-10 | 4kw | 2% | 145*80*140mm | 75*57mm | Copper |
OCL-15 | 5.5kw | 145*80*140mm | 75*57mm | Copper |
OCL-20 | 7.5kw | 150*80*140mm | 75*57mm | Copper |
OCL-30 | 11kw | 170*120*140mm | 80*65mm | Copper |
OCL-40 | 15kw | 170*120*140mm | 80*65mm | Copper |
OCL-50 | 18kw | 170*120*140mm | 80*65mm | Copper |
OCL-60 | 22kw | 170*125*140mm | 80*65mm | Copper |
OCL-80 | 30kw | 210*145*175mm | 110*97mm | Copper |
OCL-110 | 37kw | 210*145*175mm | 110*97mm | Copper |
OCL-125 | 45kw | 210*145*175mm | 110*97mm | Copper |
OCL-150 | 55kw | 210*150*175mm | 110*97mm | Copper |
OCL-200 | 75kw | 245*180*220mm | 130*118mm | Copper |
OCL-250 | 90/93kw | 245*180*220mm | 130*118mm | Copper |
OCL-280 | 110kw | 250*185*220mm | 130*120mm | Copper |
OCL-300 | 132kw | 250*185*220mm | 130*120mm | Copper |
OCL-400 | 160kw | 280*220*240mm | 130*135mm | Copper |
OCL-450 | 187kw | 280*200*240mm | 130*135mm | Copper |
OCL-500 | 200kw | 280*200*240mm | 130*135mm | Copper |
OCL-600 | 220/250kw | 280*200*280mm | 130*135mm | Copper |
OCL-800 | 280/315kw | 320*240*285mm | 170*135mm | Copper |
OCL-900 | 350kw | 355*290*335mm | 200*165mm | Copper |
OCL-1000 | 355/400kw | 355*290*335mm | 200*165mm | Copper |
OCL-1200 | 480/500kw | 355*290*335mm | 200*165mm | Copper |
OCL-1500 | 560/630kw | 355*295*340mm | 200*165mm | Copper |
DiagramInspection and acceptance1. When accepting the reactor, the user should check the outer packaging. If any damage or abnormality is found, the user should take a photo for evidence immediately, and immediately open the box for inspection to check whether the reactor is damaged, whether the product parts are damaged or displaced, tightly Whether the firmware is loose, whether the insulation is damaged, whether there are traces of dirt on the surface of the coil, etc.
2. The user should check it in time after receiving the reactor. According to the packing list and nameplate, check whether the product and its model, rated current, rated voltage, rated frequency, rated reactance rate, rated inductance value, number of phases, etc. are consistent with the order contract. Check whether the factory documents are complete and whether the accessories are consistent with the packing list.
3. Check whether the reactor is damaged during transportation, whether the product parts are damaged and displaced, whether the fasteners are loose, whether the insulation is damaged, whether there are traces of dirt on the surface of the coil, etc.
4. After the product is unpacked and checked, if it is not put into operation immediately, it should be repackaged and placed in a safe place indoors to prevent damage and theft.Maintenance1. In a dry and clean place, check once a year, in other places with serious pollution, check once every three or six months.
2. During the inspection, if too much dust is found to accumulate, it must be removed to ensure air circulation and prevent insulation breakdown. Use compressed air to remove dust from the ventilation duct.
3. Check whether the fasteners and connectors are loose, whether there are traces of rust and corrosion on the conductive parts and other parts, and observe whether there are traces of creep-age on the insulating surface.
4. There must be measures to prevent small animals from entering the reactor room to avoid accidents.
5. Always observe the temperature change of the reactor, and contact relevant personnel for consultation in time.
6. The installation, test, operation and maintenance of the reactor must be undertaken by qualified professionals.1. Can I get some samples?
Yes.Sample is available for quality check and market test.But you have to pay for it.
2. What's delivery time?
It usually takes about 3-5 working days for small order and 10-15 days for big order.
3. What's your payment terms?
We usually accept all kinds of payment terms.Such as T/T, L/C, Western Union and Cash.
4. What's your warranty terms ?
We offer 18 months warranty time.
5. Do you have the products in stock?
Depending on your request, we have standard models in stock. Some special products and big order will be newly produced according to your order.
6. Can I mix different power in one container?
Yes. Different models can be mixed up in one container, even one order.
7. How does your factory control product quality?
Quality is priority ,we always attach importance to quality control from the beginning to the end of the production .Every product will be fully assembled and carefully tested before packing and shipping.
8. Can you sell spare parts?
If you are using CHIFON products.we can sell spare parts to you.But we couldn't sell the half-finished products.
9. I would like to know if you have a partner for exporting?
Yes, our company have the right to export and can sell electrical product all over the world.
10. Can you make the inverter and soft starter control boards ?
Yes, we have a lot of experience to design frequency inverters and soft starter cabinets according to your request.But you can send us the wiring diagram.
11. Can the inverter connect with computer?
Yes, all inverters have built-in RS485 port and support Modbus communication protocol.
12. How can I trust you?
Our company's values are integrity, responsibility, innovation and cooperation and our company has been audited and approved CE, ISO9001. Assessment report could be sent to you by e-mail. Also we are the made-in-china's gold supplier.
Address:
No. 25 Xianxing Rd, Xianlin Industrial Park, Hangzhou, Zhejiang, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics, Industrial Equipment & Components, Manufacturing & Processing Machinery
Company Introduction:
Zhejiang Chifon electric Co., Ltd. is a high-tech enterprise specializing in research, development, manufacture and sales of electric drive, industrial control and motor energy saving technology products.
The company has completely independent intellectual property rights and several national patent innovation technologies. It has always adhered to technological innovation, with the goal of continuously meeting customer s needs, and has always adopted the design philosophy of high quality, high precision, high efficiency and low maintenance. It has gradually become a domestic and foreign supplier of electrical transmission equipment that is worth relying on.
The company′s products include general frequency conversion drives, special industrial application planes, integrated solutions and new energy products. The company′s research and development team gathers numerous professional and technical personnel at home and abroad, and continuously innovates on the basis of mastering high-performance vector frequency conversion technology and servo technology platforms to realize technological breakthroughs in various related fields. This enables Chifon to provide customers with the most suitable products and solutions to meet their requirements in terms of high efficiency, energy conservation, environmental protection and overall cost control.
Our inverter specifications:
1.220V ~ 240V FPR500A-S2 series single-phase input& three phase output, power section: 0.75kw ~ 2.2kw
2.380V ~ 460V FPR500A-T4 series three-phase input&output, power section: 0.75kw ~ 710kw
3.380V~460V mini type FPR500M-T4 series three-phase input&output, power section: 0.75kw~22kw
4. Customized 220V ~ 240V FPR500A-T2 series three-phase input&output
5. Customized FPR500Z series 220V three-phase input& 380V output
6. FPR500E is available for synchronous motors like FPR500A and FPR500M.
High-quality products, continuously updated technology and high-quality service have made the reputation of the cadres increasingly popular.