• Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
  • Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
  • Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
  • Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
  • Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
  • Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor

Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor

Type: Choke Inductor
Structure: Inductive Choke
Working Frequency: Low Frequency
Samples:
US$ 78.68/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor pictures & photos
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
US $84.37-87.89 / Piece
Min. Order: 1 Piece
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
ACL-80
Structure of Winding
Multilayer Coil
Nature of Operation
Choke Coil
Structure of Magnetizer
Copper Coil
Range of Application
Protecion
Packaging Form
Generic
Brand
Chifon
Inductor Value
Variable Inductor
Insulation Level
Fh
Reactance Rate
1% 2% 3% 4%
Noise
Less Than 65dB
Protection Grade
IP11
Insulation Resistance
Greater Than 100ohm
Transport Package
Carton
Specification
210*135*175mm
Trademark
CHIFON
Origin
China
HS Code
8504500000
Production Capacity
5000 Pieces/Month

Packaging & Delivery

Package Size
22.00cm * 15.50cm * 19.50cm
Package Gross Weight
2.000kg

Product Description

Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
 
Model ACL-80 Operating tempeture -25ºC~45ºC
Power 30kw Operation relative humidity Not exceeding 90%
Size(L*W*H) 210*135*175mm Dielectric  Strength Iron core - winding resistance 3000V/50HZ, no arc breakdown for 60 seconds
Installation dimensions 80*65mm Hs Code 8504500000
Material Copper Warranty 18 months

An input reactor that is part of the power supply system for the frequency converter. Reactors are sometimes used to protect the frequency converter and other equipment from voltage spikes, harmonics, or other electrical disturbances.


A three-phase incoming reactor, also known as a commutation reactor, is used at the input end of a frequency converter. It passes through alternating current and its function is to limit the voltage on both sides of the grid when the frequency converter is commutating, suppress harmonics and the rise rate of closing current, and decouple the frequency converter group. It can limit the jumping of the power grid and the surge current generated during the operation of the power grid system to protect terminal electrical equipment and suppress harmonic interference.
 
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor

Parameter
 
Incoming Reactor for Frequency Converter
Model Power Voltage drop(V) Dimension(L*W*H) Installation dimensions(L*W) Material
ACL-10 4kw 2% 145*80*140mm 75*57mm Copper
ACL-15 5.5kw 145*80*140mm 75*57mm Copper
ACL-20 7.5kw 145*80*140mm 75*57mm Copper
ACL-30 11kw 170*120*140mm 80*65mm Copper
ACL-40 15kw 170*120*140mm 80*65mm Copper
ACL-50 18kw 170*120*140mm 80*65mm Copper
ACL-60 22kw 170*120*140mm 80*65mm Copper
ACL-80 30kw 210*140*175mm 110*97mm Copper
ACL-110 37kw 210*140*175mm 110*97mm Copper
ACL-125 45kw 210*140*175mm 110*97mm Copper
ACL-150 55kw 210*140*175mm 110*97mm Copper
ACL-200 75kw 245*180*220mm 130*118mm Copper
ACL-250 90/93kw 245*180*220mm 130*120mm Copper
ACL-280 110kw 245*180*220mm 130*120mm Copper
ACL-300 132kw 245*185*220mm 130*120mm Copper
ACL-400 160kw 280*200*240mm 130*115mm Copper
ACL-450 187kw 280*200*240mm 130*115mm Copper
ACL-500 200kw 280*200*240mm 130*115mm Copper
ACL-600 220/250kw 280*200*280mm 130*115mm Copper
ACL-800 280/315kw 320*230*285mm 170*140mm Copper
ACL-900 350kw 320*230*285mm 170*140mm Copper
ACL-1000 355/400kw 320*240*295mm 170*140mm Copper
ACL-1200 480/500kw 355*275*330mm 200*155mm Copper
ACL-1400 560/630kw 355*285*340mm 200*155mm Copper


Diagram

Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming ReactorLow Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor

Inspection and acceptance
1. When accepting the reactor, the user should check the outer packaging. If any damage or abnormality is found, the user should take a photo for evidence immediately, and immediately open the box for inspection to check whether the reactor is damaged, whether the product parts are damaged or displaced, tightly Whether the firmware is loose, whether the insulation is damaged, whether there are traces of dirt on the surface of the coil, etc.
2. The user should check it in time after receiving the reactor. According to the packing list and nameplate, check whether the product and its model, rated current, rated voltage, rated frequency, rated reactance rate, rated inductance value, number of phases, etc. are consistent with the order contract. Check whether the factory documents are complete and whether the accessories are consistent with the packing list.
3. Check whether the reactor is damaged during transportation, whether the product parts are damaged and displaced, whether the fasteners are loose, whether the insulation is damaged, whether there are traces of dirt on the surface of the coil, etc.
4. After the product is unpacked and checked, if it is not put into operation immediately, it should be repackaged and placed in a safe place indoors to prevent damage and theft.


Maintenance
1. In a dry and clean place, check once a year, in other places with serious pollution, check once every three or six months.
2. During the inspection, if too much dust is found to accumulate, it must be removed to ensure air circulation and prevent insulation breakdown. Use compressed air to remove dust from the ventilation duct.
3. Check whether the fasteners and connectors are loose, whether there are traces of rust and corrosion on the conductive parts and other parts, and observe whether there are traces of creep-age on the insulating surface.
4. There must be measures to prevent small animals from entering the reactor room to avoid accidents.
5. Always observe the temperature change of the reactor, and contact relevant personnel for consultation in time.
6. The installation, test, operation and maintenance of the reactor must be undertaken by qualified professionals.


Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming ReactorLow Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor

Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor

Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming ReactorLow Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor

1. Can I get some samples?
  Yes.Sample is available for quality check and market test.But you have to pay for it.

2. What's delivery time?
  It usually takes about 3-5 working days for small order and 10-15 days for big order.

3. What's your payment terms?
  We usually accept all kinds of payment terms.Such as T/T, L/C, Western Union and Cash.

4. What's your warranty terms ?
  We offer 18 months warranty time.

5. Do you have the products in stock?
  Depending on your request, we have standard models in stock. Some special products and big order will be newly produced         according to your order.

6. Can I mix different power in one container?
   Yes. Different models can be mixed up in one container, even one order.

7. 
How does your factory control product quality?
  Quality is priority ,we always attach importance to quality control from the beginning to the end of the production .Every product will be fully assembled and carefully tested before packing and shipping.

8. Can you sell spare parts?
  If you are using CHIFON products.we can sell spare parts to you.But we couldn't sell the half-finished products. 

9. I would like to know if you have a partner for exporting?
  Yes, our company have the right to export and can sell electrical product all over the world.

10. Can you make the inverter and soft starter control boards ?
  Yes, we have a lot of experience to design frequency inverters and soft starter cabinets according to your request.But you can send us the wiring diagram.

11. Can the inverter connect with computer?
  Yes, all inverters have built-in RS485 port and support Modbus communication protocol. 

12. How can I trust you?
  Our company's values are integrity, responsibility, innovation and cooperation and our company has been audited and approved CE, ISO9001. Assessment report could be sent to you by e-mail. Also we are the made-in-china's gold supplier.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor pictures & photos
Low Frequency 1000V 50/60Hz Input Reactor Three Phase Incoming Reactor
US $84.37-87.89 / Piece
Min. Order: 1 Piece
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
10000000 RMB
Plant Area
501~1000 square meters