Application: High-performance Transducer, Three Phase Transducer, General Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Samples:
US$ 103.38/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump pictures & photos
SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump
US $99.4-103.38 / Piece
Min. Order: 1 Piece
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Advantage of FPR500M
  • Company Information
  • Packaging & Shipping
  • Certifications
  • After Sales Service
Overview

Basic Info.

Model NO.
FPR500M-4.0G-T4
Switch Mode
PWM Control
Main Circuit Type
Current
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Simple Type, Constant Torque Universal Type
Brand
Chifon
Input Frequency
50/60Hz
Input Voltage
380V-460V
Output Voltage
380V-460V
Motor Power
4kw
Transport Package
Carton or Wooden Packing
Specification
24*18*21cm
Trademark
Chifon
Origin
China
HS Code
8504409999
Production Capacity
5000PC/Month

Packaging & Delivery

Package Size
18.50cm * 11.80cm * 15.70cm
Package Gross Weight
2.000kg
Lead Time
2 days (1 - 10 Pieces)
To be negotiated ( > 10 Pieces)

Product Description

Model No. FPR500M-4.0G-T4 Size(H*W*D) 18.5*11.8*15.7cm
Brand CHIFON Net Weight 2KG
Input Voltage Three phases 380V-460V Warranty 18 months
Output Voltage Three phase 380V-460V Control Mode VF, SVC, VC, Torque Control, Tension Control
Rated Output Current 9A Production Capacity 5000pcs/months
Adaptive motor Three phases 3.7kw/4kw Hs Code 8504409940
 
Product Description

FPR series adopts a new generation of special digital signal processors (DSP) for motor control of TI Company, USA. Its frequency can reach up to 150 MHz.

And adopt the latest generation Infineon IGBT module, combined with the 175 ºC maximum junction temperature characteristics. This series further reduces the switching loss by using innovative PWM modulation, so that the driver can be used normally in the environment of 50 ºC .
SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump

SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump
SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump
SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump
SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump
SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump
SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump


 
Power Class Single-phase 220v±15% 
Three-phase 380V±15%
Input frequency 47~63Hz
Output frequency range 0~500Hz
Overload capability G type:150% rated current for 60s;   
180% rated current for 3s
P type:120% rated current for 60s;
150% rated current for 3s
Torque boost Auto Torque boost Manual Torque boost; 0.1%~30.0%.
V/F curve V/F Four modes : Line , Multi-point , Square V/F curve, V/F separation
Jog control Jog frequency range:0.00Hz to F0-10(Max frequency)
Accelerate/Decelerate curve Line or S-curve Acc/Dec mode, four kinds of Acc/Dec time Range
of Acc/Dec Time0.0~65000.00s.
DC brake DC brake frequency: 0.00Hz to Maximum frequency
brake time: 0.0 to 36.0s
brake current value: 0.0 to 100%
Simple PLC, Multi-speed 16-speed operating through built-in PLC or control terminal
Built-in PID Close loop control system can be formed easily by using PID
Automatic voltage
regulating (AVR)
Output voltage is regulated when voltage of the power network changes
Overvoltage and over current
stall control
During operation automatically limits the inverter output current
and bus voltage, to prevent fan over current and overvoltage trip.
Rapid current limiting
function
Minimizing flow failures, protect the normal operation of the inverter
Instantaneous stop non-stop Load feedback energy compensation voltage is reduced and continues to maintain a short time when change is momentarily interrupted.
Speed tracking start For high-speed rotation of the motor speed identification, impact-
free smooth start
Rapid current limit Rapid software and hardware limiting technology to avoid
frequent converter over current fault.
Virtual IO Five sets of virtual DO, five sets of virtual DI, enables easy logic control.
Timing Control Timing control: set the time range 0.0Min~6500.0Hour
Multi-motor
switch
Two independent motor parameters, enabling two motors switching control
Bus Support Two independent Modbus communication, CAN-Link
Command source Given the control panel, control terminal, serial communication port given. It
can be switched by a variety of ways.
Torque boost Auto Torque boost Manual Torque boost  ; 0.1%~30.0%.
Frequency source Nine kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways.
Auxiliary
frequency source
Nine kinds of auxiliary frequency source. Flexible implementation of auxiliary
frequency tuning, frequency synthesis.
Input terminal Six digital input terminals, one only supports 50khz high pulse input
Two analog input terminals, one support 0V~10V voltage input
One support 0 ~ 10V voltage input or 0 ~ 20mA current input
Output
terminal
One high-speed pulse output terminal (optional open collector type), support of
square wave 0 ~ 50kHz signal output
One digital output terminal
One relay output terminals
Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V
voltage output
Display and operation  
LED display Display parameters and status information
The key lock and function selection Achieve some or all of the keys locked, scope definition section keys
to prevent misuse.
Protection function Input/output phase failure protection ,Overcurrent protection ;Over
voltage protection; Undervoltage protection; Overheat protection ;
Overload protection
Options Brake assembly, PG card
Environment  
Application environment In-door, free from direct sunlight, dust , corrosive gas, combustible gas, oil mist , steam , water drop and salt .
Altitude Lower than 1000m
Vibration Less than 5.9m/s(0.6g)

Product name and nameplate identification

SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump

Standard Wiring Diagram

SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump
 
Advantage of FPR500M
Low-cost frequency inverter Chifon FPR 500A series frequency inverter Chifon FPR 500M series frequency inverter
Disadvantages
1.Simplify the design and reduce the production cost.
2. The purchased components are mainly cheap brands, and the consistency of components cannot be guaranteed.    
3. The production process is backward, which barely meets the technical requirements of inverter products.
4. After-sales service cannot be guaranteed.
1. CHIFON factory focuses on products, and its technology development starts early. our technical department has the R&D ability to accept OEM orders.
2. Key components such as drive circuit and electrolytic capacitor used in frequency converter are purchased from leading brands.
3. The mature production process fully meets the technical requirements of frequency converter production.
4.18 months warranty period, after-sales service is guaranteed
1. The raw materials and production process are the same as FPR500 A series.
2. Lower cost with simplified design.
3. A neat solution with Less volume, weight and transportation cost domestic and abroad. 
4. 18 months warranty period, after-sales service is guaranteed
Advantages: the price is very low Advantages: The price is lower than the international leading brands, and cost-effective. Advantages: The price is lower than FPR500A series, which can meet customers with low budget.






Overall Comparison of 0.75kw-2.2kw between FPR500A series and FPR500M series


SIZE:24*18*21CM
WEIGHT:2kg


SIZE:22*14*19CM
WEIGHT: 1.3kg

Company Information

About us
    Zhejiang Chifon electric co,.ltd. is a high-tech enterprise specializing in research, development, manufacture, and sales of electric drive, industrial control, and motor energy-saving technology products.
    We insist on the principle of developing of "customer-centric and technological solution" to provide you with precise speed control and energy saving!
SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump

Packaging & Shipping

SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump

SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump
 
Certifications

 

SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump
 
After Sales Service

 Daily inspection items

Before powering on the inverter, check the temperature and humidity of the surrounding environment. Excessive temperature will cause the inverter to overheat and alarm. In severe cases, it will directly damage the inverter's power components and short circuit; excessively humid air will cause a direct short circuit inside the inverter. When the inverter is running, pay attention to whether the cooling system is working, such as: whether the air duct is smooth and whether the fan has abnormal sound. Inverters with a relatively high protection level such as inverters above IP20 can be installed directly open; inverters below IP20 should generally be installed in cabinets, so how does the cooling effect of the inverter cabinet directly affect the normal operation of the inverter? Exhaust systems such as whether the fan rotates smoothly, and whether there is dust and obstructions in the air inlet are all places that we can't ignore in daily inspections. Whether the motor reactor, transformer, etc. are overheated and smelly; whether the inverter and motor have abnormal noise; whether the inverter panel current display is too large or the current variation is too large, whether the output UVW three-phase voltage and current are balanced, etc.

 

Regular maintenance

Clean the air duct and dust inside the air filter. Check whether the screws, bolts, and plug-in are loose and whether the input and output reactors have short circuits to the ground and the phase-to-phase resistance. The normal should be greater than tens of megohms. Whether the conductors and insulators are corrupted, if necessary, wipe them with alcohol in time. When conditions permit, it is necessary to use an oscilloscope to measure the stability of the output voltage of each circuit of the switching power supply, such as 5V, 12V, 15V, 24V, and other voltages. Is there any distortion in the method of measuring each waveform of the driver circuit? Whether the UVW interphase waveform is a sine wave. Check if there is any trace of fire in the contactor of the contactor. If it is serious, replace the new product with the same model or larger than the original capacity; confirm the correctness of the control voltage and carry out the sequence protection action test; confirm that the protection display circuit is not abnormal; confirm that the inverter is running alone the balance of the output voltage.

It is recommended that periodic inspections should be conducted once a year.
 

Replacement of spare parts

 

The inverter is composed of various components, some of which will gradually reduce and aging after long-term work. This is also the main reason for the failure of the inverter. In order to ensure the long-term normal operation of the equipment, the following components should be replaced regularly:

 

(1) Cooling fan

The power module of the inverter is the most serious device that generates heat. The heat generated by a continuous operation must be discharged in time. The life of the general fan is about 10kh ~ 40kh. According to the continuous operation of the inverter, it is converted to 2 to 3 years. The fan must be replaced once. The direct cooling fan has two wires and three wires. One of the two wires of the fan is positive and the other is negative. 1. There is a detection line outside the negative pole, please pay attention when replacing it, otherwise, it will cause the inverter overheating alarm. The AC fan is generally divided into 220V and 380V, and the voltage level should not be mistaken when replaced.

 

(2) Filter capacitor

Intermediate DC loop filter capacitor: also known as an electrolytic capacitor, its main function is to smooth the DC voltage and absorb the low-frequency harmonics in DC. The heat generated by its continuous operation plus the heat generated by the inverter itself will accelerate the drying up of its electrolyte. Directly affect the size of its capacity. Under normal circumstances, the service life of the capacitor is 5 years. It is recommended to regularly check the capacitance of the capacitor once a year. Generally, its capacity is reduced by more than 20% and should be replaced.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump pictures & photos
SGS Qualified IGBT-Based Variable Frequency Drive Fpr500m 3.7kw/4kw for Water Pump
US $99.4-103.38 / Piece
Min. Order: 1 Piece
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
10000000 RMB
Plant Area
501~1000 square meters